after running the simulation for airflows I see only an error:
...
reversed flow in 23 faces on pressure-outlet 4.
reversed flow in 31 faces on pressure-outlet 5.
reversed flow in 35 faces on pressure-outlet 6.
reversed flow in 38 faces on pressure-outlet 7.
reversed flow in 52 faces on pressure-outlet 8.
reversed flow in 8 faces on pressure-outlet 9.
reversed flow in 8 faces on pressure-outlet 13.
Error: divergence detected in AMG solver: temperature
Error Object: ()
why?.....how to fixed it?.....
solution for that error: in windows of FLUENT click SOLVE then click Initialize-Initialize-set Velocity Magnitude = 1 or other values then click Reset-Apply-Close.
Another solution is to click Initialize-Initialize- then click Init...
...continuousimprovement of lasmanp's thesis...
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment